    Heat pumps from 10 ÷ 50 kW

  • 002

    Heat pumps from 50 ÷ 200 kW

  • 003

    Heat pumps from 200 ÷ 500 kW

     

Air-to-Water compact type heat pumps

The main purpose of the heat pump air-to-water type is air conditioning, heating and cooling. Can be used in all conditions because the source (sink) of the heat energy is the air.

Heat pumps are aggregated as a compact unit and can easily be connected to the electrical and hydraulic network.

They are intended to be installed outside the building on the roof, terrace etc. Modern design and low noise level permit its use in all conditions. Control cabinet with electronic parts can be made as integral or separated part of the system.

All units can be made as "industrial" type.

They are primarily intended for cooling in summer and heating in the transitional periods.

Application

  • Installation of air conditioning
  • Installation of underfloor, air or other heating systems
  • The installation of the domestic hot water
  • Cooling or heating in technological processes
  • The installation of hot sanitary water preparation
  • Heat pumps water-to-water type are aggregated as a compact unit and they can easily be connected to the electrical and hydraulic networks
  • Product Characteristics

  • Scroll compressors installed either separately, in tandem or in trio
  • R 407, R 410a and R 134a, refrigerants
  • Coaxial, shell tube or plate heat exchangers
  • Coaxial, shell tube or plate heat capacitors
  • Axial fans and heat exchanger fins
  • Programmed operating time
  • Electronic compressor protection
  • Protection against flow loss (using mechanical reinforcement)
  • Electronic control of the main power supply
  • Additional mechanical and electronic protective reinforcements
  • Microprocessor controlled process
  • Soundproofed housing and silent system operations
  • Additional informations

    Chillers and heat pumps are compact aggregates, designed for direct installation on the required place. After connecting to the network, its hydraulic and electrical power generators are immediately ready for operation.

  • Heat pumps of power range 10 ÷ 50 kW
  • Heat pumps of power range 50 ÷ 200 kW
  • Heat pumps of power range 200 ÷ 500 kW
  • Heat pumps of power range 10 ÷ 50 kW

    AK TP VW   48 61 72 81 108 125 160 216
    COOLING CAPACITY
    Operating mode: 12/7 (°C)
    Outside air temperature: +35 (°C)
    kW 10,05 12,75 14,65 16,50 22,80 26,70 32,90 45,60
    Apsorbed power kW 3,59 4,46 5,11 5,81 7,51 8,85 11,30 15,02
    HEATING CAPACITY
    Outside air temperature: +7 (°C)
    Operating mode: 30/35 (°C)
    kW 11,15 14,25 4,43 18,25 25,00 29,20 35,70 50,00
    Apsorbed power kW 3,13 3,80 4,43 5,00 6,55 7,65 9,82 13,10
    HEATING CAPACITY
    Outside air temperature: +7 (°C)
    Operating mode: 45/40; 50/45 (°C)
    kW 11,00 14,05 15,85 17,90 24,50 28,60 34,80 49,00
    Apsorbed power kW 3,44 4,20 4,86 5,52 7,16 8,41 10,80 14,32
    Number of compressors units, Scroll kom 1 1 1 1 1 1 1 2
    Cooling fluid                  
    Number of freon circuits kom 1 1 1 1 1 1 1 1
    Secondary circuit flow - installation l/s 0,5 0,64 0,72 0,84 1,12 1,4 1,72 2,39
    Preassure drop in the secondary circuit kPa 10 15 20   25 30 35 35
    Secondary circuit connections: R(NO) R5/4" R5/4" R5/4" R5/4" R5/4" R5/4" R6/4" R2"
    Dimensions A x B x H mm 1050 x 380 x 1450 950 x 800 x 1600 2200 x 900 x 1250

    Heat pumps of power range 50 ÷ 200 kW

    AK TP VW   250 320 380 480 500 570 640 760
    COOLING CAPACITY
    Operating mode: 12/7 (°C)
    Outside air temperature: +35 (°C)
    kW 53,40 65,80 77,60 98,70 106,80 116,70 131,60 155,20
    Apsorbed power kW 17,70 22,60 27,00 33,90 35,40 40,50 45,20 54,00
    HEATING POWER
    Outside air temperature: +7 (°C)
    Operating mode: 30/35 (°C)
    kW 58,40 71,40 85,80 107,10 116,80 128,70 142,80 171,60
    Apsorbed power kW 15,30 19,64 23,50 29,46 30,60 35,25 39,28 47,00
    HEATING CAPACITY
    Outside air temperature: +7 (°C)
    Operating mode: 45/40; 50/45 (°C)
    kW 57,20 69,60 83,80 104,40 114,40 125,70 139,20 167,60
    Apsorbed power kW 16,82 21,60 25,70 32,40 33,64 38,55 43,20 51,40
    Number of compressor units, Scroll kom 2 2 2 3 4 3 4 4
    Cooling fluid                  
    Number of freon circuits kom 1 1 1 1 2 1 2 2
    Secondary circuit flow - installation l/s 2,64 3,44 4,10 5,10 5,30 5,55 6,11 8,21
    Preassure drop in the secondary circuit kPa 40 35 40 45 45 45 30 45
    Secondary circuit connections: R(NO) R2" NO65 NO65 NO65 NO80 NO80 NO80 NO80
    Dimensions A x B x H mm 2200 x 900 x 1600 3200 x 1100 x 1850

    Heat pumps of power range 200 ÷ 500 kW

    AK TP VW   960 1000 1240 1520 1860
    COOLING CAPACITY
    Operating mode: 12/7 (°C)
    Outside air temperature: +35 (°C)
    kW 197,40 206,80 256,40 322,80 384,60
    Apsorbed power kW 67,80 71,20 88,40 105,20 132,60
    HEATING CAPACITY
    Outside air temperature: +7 (°C)
    Operating mode: 30/35 (°C)
    kW 171,60 228,00 282,70 349,60 424,20
    Apsorbed power kW 58,92 61,20 76,20 91,20 114,30
    HEATING CAPACITY
    Outside air temperature: +7 (°C)
    Operating mode: 45/40; 50/45 (°C)
    kW 208,80 223,60 276,40 341,20 414,50
    Apsorbed power kW 64,80 67,60 84,00 100,00 126
    Number of compressors units, Scroll kom 6 4 4 4 6
    Cooling fluid            
    Number of freon circuits kom 2 2 2 2 2
    Secondary circuit flow - installation l/s 10,25 10,90 13,50 16,70 20,30
    Preassure drop in the secondary circuit kPa 40 40 40 45 45
    Secondary circuit connections: R(NO) NO100 NO100 NO125 NO125 NO125
    Dimensions A x B x H mm 3700 x 1100 x 2200

    About us

    "Alfa Clima" is founded 1995 as a private company specialised in manufacturing thermotechnical equipments and systems for climatisation, cooling and ventilation.

    Production program

    • Climatisation objects heat pumps
    • Geo-thermal heat pumps
    • Technological heating & cooling
    • Heat pumps for dry air

    Contact

    • About us
    • Contact
    • Facebook
    • Twitter
    • LinkedIn
    • Google+

    Need more!

    If you have any questions, please fill the form . You will get an answer very soon.

    www.3kom.co.rs Web site development - 3kom Knjaževac

    www.alfaclima.co.rs