The main purpose of the heat pump air-to-water type is air conditioning, heating and cooling. Can be used in all conditions because the source (sink) of the heat energy is the air.
Heat pumps are aggregated as a compact unit and can easily be connected to the electrical and hydraulic network.
They are intended to be installed outside the building on the roof, terrace etc. Modern design and low noise level permit its use in all conditions. Control cabinet with electronic parts can be made as integral or separated part of the system.
All units can be made as "industrial" type.
They are primarily intended for cooling in summer and heating in the transitional periods.
Chillers and heat pumps are compact aggregates, designed for direct installation on the required place. After connecting to the network, its hydraulic and electrical power generators are immediately ready for operation.
AK TP VW | 48 | 61 | 72 | 81 | 108 | 125 | 160 | 216 | |
COOLING CAPACITY Operating mode: 12/7 (°C) Outside air temperature: +35 (°C) |
kW | 10,05 | 12,75 | 14,65 | 16,50 | 22,80 | 26,70 | 32,90 | 45,60 |
Apsorbed power | kW | 3,59 | 4,46 | 5,11 | 5,81 | 7,51 | 8,85 | 11,30 | 15,02 |
HEATING CAPACITY Outside air temperature: +7 (°C) Operating mode: 30/35 (°C) |
kW | 11,15 | 14,25 | 4,43 | 18,25 | 25,00 | 29,20 | 35,70 | 50,00 |
Apsorbed power | kW | 3,13 | 3,80 | 4,43 | 5,00 | 6,55 | 7,65 | 9,82 | 13,10 |
HEATING CAPACITY Outside air temperature: +7 (°C) Operating mode: 45/40; 50/45 (°C) |
kW | 11,00 | 14,05 | 15,85 | 17,90 | 24,50 | 28,60 | 34,80 | 49,00 |
Apsorbed power | kW | 3,44 | 4,20 | 4,86 | 5,52 | 7,16 | 8,41 | 10,80 | 14,32 |
Number of compressors units, Scroll | kom | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 |
Cooling fluid | |||||||||
Number of freon circuits | kom | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Secondary circuit flow - installation | l/s | 0,5 | 0,64 | 0,72 | 0,84 | 1,12 | 1,4 | 1,72 | 2,39 |
Preassure drop in the secondary circuit | kPa | 10 | 15 | 20 | 25 | 30 | 35 | 35 | |
Secondary circuit connections: | R(NO) | R5/4" | R5/4" | R5/4" | R5/4" | R5/4" | R5/4" | R6/4" | R2" |
Dimensions A x B x H | mm | 1050 x 380 x 1450 | 950 x 800 x 1600 | 2200 x 900 x 1250 |
AK TP VW | 250 | 320 | 380 | 480 | 500 | 570 | 640 | 760 | |||
COOLING CAPACITY Operating mode: 12/7 (°C) Outside air temperature: +35 (°C) |
kW | 53,40 | 65,80 | 77,60 | 98,70 | 106,80 | 116,70 | 131,60 | 155,20 | ||
Apsorbed power | kW | 17,70 | 22,60 | 27,00 | 33,90 | 35,40 | 40,50 | 45,20 | 54,00 | ||
HEATING POWER Outside air temperature: +7 (°C) Operating mode: 30/35 (°C) |
kW | 58,40 | 71,40 | 85,80 | 107,10 | 116,80 | 128,70 | 142,80 | 171,60 | ||
Apsorbed power | kW | 15,30 | 19,64 | 23,50 | 29,46 | 30,60 | 35,25 | 39,28 | 47,00 | ||
HEATING CAPACITY Outside air temperature: +7 (°C) Operating mode: 45/40; 50/45 (°C) |
kW | 57,20 | 69,60 | 83,80 | 104,40 | 114,40 | 125,70 | 139,20 | 167,60 | ||
Apsorbed power | kW | 16,82 | 21,60 | 25,70 | 32,40 | 33,64 | 38,55 | 43,20 | 51,40 | ||
Number of compressor units, Scroll | kom | 2 | 2 | 2 | 3 | 4 | 3 | 4 | 4 | ||
Cooling fluid | |||||||||||
Number of freon circuits | kom | 1 | 1 | 1 | 1 | 2 | 1 | 2 | 2 | ||
Secondary circuit flow - installation | l/s | 2,64 | 3,44 | 4,10 | 5,10 | 5,30 | 5,55 | 6,11 | 8,21 | ||
Preassure drop in the secondary circuit | kPa | 40 | 35 | 40 | 45 | 45 | 45 | 30 | 45 | ||
Secondary circuit connections: | R(NO) | R2" | NO65 | NO65 | NO65 | NO80 | NO80 | NO80 | NO80 | ||
Dimensions A x B x H | mm | 2200 x 900 x 1600 | 3200 x 1100 x 1850 |
AK TP VW | 960 | 1000 | 1240 | 1520 | 1860 | |
COOLING CAPACITY Operating mode: 12/7 (°C) Outside air temperature: +35 (°C) |
kW | 197,40 | 206,80 | 256,40 | 322,80 | 384,60 |
Apsorbed power | kW | 67,80 | 71,20 | 88,40 | 105,20 | 132,60 |
HEATING CAPACITY Outside air temperature: +7 (°C) Operating mode: 30/35 (°C) |
kW | 171,60 | 228,00 | 282,70 | 349,60 | 424,20 |
Apsorbed power | kW | 58,92 | 61,20 | 76,20 | 91,20 | 114,30 |
HEATING CAPACITY Outside air temperature: +7 (°C) Operating mode: 45/40; 50/45 (°C) |
kW | 208,80 | 223,60 | 276,40 | 341,20 | 414,50 |
Apsorbed power | kW | 64,80 | 67,60 | 84,00 | 100,00 | 126 |
Number of compressors units, Scroll | kom | 6 | 4 | 4 | 4 | 6 |
Cooling fluid | ||||||
Number of freon circuits | kom | 2 | 2 | 2 | 2 | 2 |
Secondary circuit flow - installation | l/s | 10,25 | 10,90 | 13,50 | 16,70 | 20,30 |
Preassure drop in the secondary circuit | kPa | 40 | 40 | 40 | 45 | 45 |
Secondary circuit connections: | R(NO) | NO100 | NO100 | NO125 | NO125 | NO125 |
Dimensions A x B x H | mm | 3700 x 1100 x 2200 |